Search results for 'vent'
-
Duravent PPS 12" Length UV Black Straight Pipe 3" Diameter
UV Resistant Black Ploypropylene pipe for use with Venting Gas Appliances. Available in 2", 3", and 4" diameter.PolyPro is a polypropylene vent pipe for use with ANSI Category II and IV gas burning appliances, including tankless and storage water heaters, high-efficiency water heaters, condensing boilers and warm air furnaces. PolyPro is listed by Intertek to the ULC S636 standard in Canada and is rated as a Class IIA, IIB and IIC vent system suitable for exhaust temperatures up to 230°F / 110°C, and a maximum positive pressure of 15 in-w.c.$9.36 -
Duravent PPS 12" Length UV Black Straight Pipe 2" Diameter
UV Resistant Black Ploypropylene pipe for use with Venting Gas Appliances. Available in 2", 3", and 4" diameter.PolyPro is a polypropylene vent pipe for use with ANSI Category II and IV gas burning appliances, including tankless and storage water heaters, high-efficiency water heaters, condensing boilers and warm air furnaces. PolyPro is listed by Intertek to the ULC S636 standard in Canada and is rated as a Class IIA, IIB and IIC vent system suitable for exhaust temperatures up to 230°F / 110°C, and a maximum positive pressure of 15 in-w.c.$8.42 -
Duravent PPS 12" Length UV Black Straight Pipe
UV Resistant Black Polypropylene pipe for use with Venting Gas Appliances. Available in 2", 3", and 4" diameter.PolyPro is a polypropylene vent pipe for use with ANSI Category II and IV gas burning appliances, including tankless and storage water heaters, high-efficiency water heaters, condensing boilers and warm air furnaces. PolyPro is listed by Intertek to the ULC S636 standard in Canada and is rated as a Class IIA, IIB and IIC vent system suitable for exhaust temperatures up to 230°F / 110°C, and a maximum positive pressure of 15 in-w.c.$8.42 -
Duravent PPS 12" Length Straight Pipe 3" Diameter
12" Length of Polypropylene Vent Pipe for use with Venting Gas Appliances. Available in 2", 3", and 4" diameter.PolyPro is a polypropylene vent pipe for use with ANSI Category II and IV gas burning appliances, including tankless and storage water heaters, high-efficiency water heaters, condensing boilers and warm air furnaces. PolyPro is listed by Intertek to the ULC S636 standard in Canada and is rated as a Class IIA, IIB and IIC vent system suitable for exhaust temperatures up to 230°F / 110°C, and a maximum positive pressure of 15 in-w.c.
$8.19 -
Duravent PPS 12" Length Straight Pipe 2" Diameter
12" Length of Polypropylene Vent Pipe for use with Venting Gas Appliances. Available in 2", 3", and 4" diameter.PolyPro is a polypropylene vent pipe for use with ANSI Category II and IV gas burning appliances, including tankless and storage water heaters, high-efficiency water heaters, condensing boilers and warm air furnaces. PolyPro is listed by Intertek to the ULC S636 standard in Canada and is rated as a Class IIA, IIB and IIC vent system suitable for exhaust temperatures up to 230°F / 110°C, and a maximum positive pressure of 15 in-w.c.
$7.02 -
Duravent PPS 12" Length Straight Pipe
12" Length of Polypropylene pipe for use with Venting Gas Appliances. Available in 2", 3", and 4" diameter.PolyPro is a polypropylene vent pipe for use with ANSI Category II and IV gas burning appliances, including tankless and storage water heaters, high-efficiency water heaters, condensing boilers and warm air furnaces. PolyPro is listed by Intertek to the ULC S636 standard in Canada and is rated as a Class IIA, IIB and IIC vent system suitable for exhaust temperatures up to 230°F / 110°C, and a maximum positive pressure of 15 in-w.c.
$7.02 -
Caleffi Series 255 Dual Line Pump Station Return and Flow, 3 Speed
Caleffi Series 255 Dual Line Pump Station Return and Flow, 3 SpeedSolar pump stations are pre-assembled and leak-tested. Safety relief valve. Ball valves with built-in fl ow checks in return (and fl ow for dual-line models). Temperature gauges in return (and fl ow for dual-line models). Pressure gauge. Manual air vent (dual-line models only). Expansion tank connection. Connections for fl ushing and fi lling. Foam insulation. Balance/fl ow meter: ½—5 gpm scale. Pump: Grundfos UP15-100 Performance: 36 feet head / 8 gpm. Safety relief valve: 90 psi. Max. working pressure: 150 psi. Max. working temp: 360ºF. Connections: ¾" female thread. Agency approval: cULus.$506.44 -
Caleffi Series NA292 Shut Off Air Vent Valve 1/2" NPT Female to 1/2" Male
Caleffi Series NA292 Shut Off Air Vent Valve 1/2" NPT Female to 1/2" MaleShut-off for automatic air vent. Working temperature range: -20—360ºF. Max. working pressure: 150 psi.$24.01 -
Caleffi 548 Series Hydro Separator with ANSI Flanges-5" ANSI Flanged connection without Insulation ASME
Without Insulation-ASME tagged and registeredSeries 548 Hydro Separator with ANSI Flanges. This device consists of several different functional components, each meet specific requirements, typical of the circuits used in heating and air-conditioning systems. • Hydronic separator: To keep connected hydronic circuits totally independent from each other • Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided with a valved connection with discharge piping. • Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection for maintenance purposes. The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.Regular Price: $8,480.00
Special Price: $3,114.99
-
Caleffi 548 Series Hydro Separator with ANSI Flanges-4" ANSI Flanged connection w/Insulation
0Series 548 Hydro Separator with ANSI Flanges. This device consists of several different functional components, each meet specific requirements, typical of the circuits used in heating and air-conditioning systems. • Hydronic separator: To keep connected hydronic circuits totally independent from each other • Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided with a valved connection with discharge piping. • Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection for maintenance purposes. The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.Regular Price: $5,000.00
Special Price: $1,836.67