1-800-873-3507

TALK TO A REAL HUMAN!
(8am-5pm mst mon-fri)

Search results for 'outdoor whole house tankless unit'

Items 1 to 10 of 153 total

per page
Page:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5

Grid  List 

Set Descending Direction
  1. Caleffi 132 Series QuickSetter Balancing Valve with Flow Meter-1-1/4" NPT: 5-19 GPM

    Caleffi 132 Series QuickSetter Balancing Valve with Flow Meter-1-1/4" NPT: 5-19 GPM

    Balancing Valve with Flow Meter, offers direct reading of flow rate, no sight gauge clouding or scaling. Has brass valve body and flow meter, rotatable valve for flow rate adjustement, and graduated scale flow meter with magnetic movement flow rate indicator. MAX working pressure: 150 psi. Temperature range: 14-230 F. Max percentage of glycol: 50%.
    The 132 series balancing valve accurately sets the flow rate of heating and cooling transfer fluid supplied to fan coils and terminal units or where flow balancing is required in solar thermal systems. Proper hydronic system balancing ensures that the system operates according to design specifications, providing satisfactory thermal comfort with low energy consumption. The flow meter is housed in a bypass circuit on the valve body and can be shut off during normal operation. The flow meter permits fast and easy circuit balancing without added differential pressure gauges and reference charts. The balancing valve is furnished with a preformed insulation shell to optimize thermal performance or both hot and cold water systems.
    $150.54

  2. Caleffi 548 Series Hydro Separator with ANSI Flanges-3" ANSI Flanged connection w/Insulation

    Caleffi 548 Series Hydro Separator with ANSI Flanges-3" ANSI Flanged connection w/Insulation

    0
    Series 548 Hydro Separator with ANSI Flanges. This device consists of several different functional components, each meet specific requirements, typical of the circuits used in heating and air-conditioning systems. • Hydronic separator: To keep connected hydronic circuits totally independent from each other • Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided with a valved connection with discharge piping. • Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection for maintenance purposes. The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.

    Regular Price: $4,465.00

    Special Price: $1,640.14

  3. Caleffi 548 Series Hydro Separator with ANSI Flanges-4" ANSI Flanged connection w/Insulation

    Caleffi 548 Series Hydro Separator with ANSI Flanges-4" ANSI Flanged connection w/Insulation

    0
    Series 548 Hydro Separator with ANSI Flanges. This device consists of several different functional components, each meet specific requirements, typical of the circuits used in heating and air-conditioning systems. • Hydronic separator: To keep connected hydronic circuits totally independent from each other • Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided with a valved connection with discharge piping. • Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection for maintenance purposes. The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.

    Regular Price: $5,000.00

    Special Price: $1,836.67

  4. Caleffi 548 Series Hydro Separator

    Caleffi 548 Series Hydro Separator

    Hydro Separator available in 1"-2" NPT & Sweat Unions. MAX operating pressure: 150 psi. Temperature range with insulation: 32-210 F without insulation: 32-250 F. Medium: Water & Non-Hazardous Glycol solution. MAX percentage glycol: 50%.
    Series 548 Hydro Separator. This device consists of several different functional components, each meet specific requirements, typical of the circuits used in heating and air-conditioning systems. • Hydronic separator: To keep connected hydronic circuits totally independent from each other • Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided with a valved connection with discharge piping. • Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection for maintenance purposes. The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.
    $393.41

  5. Caleffi 548 Series Hydro Separator with ANSI Flanges-5" ANSI Flanged connection without Insulation ASME

    Caleffi 548 Series Hydro Separator with ANSI Flanges-5" ANSI Flanged connection without Insulation ASME

    Without Insulation-ASME tagged and registered
    Series 548 Hydro Separator with ANSI Flanges. This device consists of several different functional components, each meet specific requirements, typical of the circuits used in heating and air-conditioning systems. • Hydronic separator: To keep connected hydronic circuits totally independent from each other • Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided with a valved connection with discharge piping. • Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection for maintenance purposes. The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.

    Regular Price: $8,480.00

    Special Price: $3,114.99

  6. Webstone Sweat Isolator Flange with Drain-3/4"

    Webstone Sweat Isolator Flange with Drain-3/4"

    Webstone Sweat Isolator Flange with Drain 3/4", 1", 1-1/4", 1-1/2" and 2"
    Webstone Isolation Flanges with Drain are designed for residential and commercial use with all 2 bolt flanged circulator pumps. The unitary construction of the brass body and flange provide strength and versatility for any application where a pipe and flange meet. This valve is the only choice to use in a closed system where a large port drain and fill valve is required.Additional wing style "T" handle included with mounting nuts and bolts.
    $26.58

  7. Caleffi 548 Series Hydro Separator with ANSI Flanges-6" ANSI Flanged connection without Insulation ASME

    Caleffi 548 Series Hydro Separator with ANSI Flanges-6" ANSI Flanged connection without Insulation ASME

    Without Insulation ASME tagged and registered
    Series 548 Hydro Separator with ANSI Flanges. This device consists of several different functional components, each meet specific requirements, typical of the circuits used in heating and air-conditioning systems. • Hydronic separator: To keep connected hydronic circuits totally independent from each other • Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided with a valved connection with discharge piping. • Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection for maintenance purposes. The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.

    Regular Price: $10,280.00

    Special Price: $3,776.19

  8. Caleffi Series 553 Automatic Filling Units 1/2"Union NPT Male Inlet with 1/2" NPT Female Outlet

    Caleffi Series 553 Automatic Filling Units 1/2"Union NPT Male Inlet with 1/2" NPT Female Outlet

    Caleffi Series 553 Automatic Filling Units
    The AutoFill™ automatic filling valve is a pressure reducing valve with a compensating seat, an inlet filter, a shut-off valve and a check valve. It is installed on the water inlet piping in sealed heating systems, and its main function is to maintain the pressure of the system to a preset value, automatically filling up with water as required. This valve has been designed as pre-adjustable, which means it can be adjusted at the required pressure value before charging the system. After installation, during the filling or topping-off phase, the water feed will stop automatically when the set pressure is reached. There are no levers to flip or valve to close. Preassembled with the backflow preventer, it features an atmospheric vent which is designed to protect drinking water systems from return flow, caused by back-siphoning or backpressure, of contaminated fluids. The 573 series has been specifically certified to standards CSA B64.3 and ASSE 1012.
    $50.39

  9. Caleffi Series 676 Two-way Thermoelectric Zone Valve Including Actuator

    Caleffi Series 676 Two-way Thermoelectric Zone Valve Including Actuator

    Caleffi Series 676 Two-way Thermoelectric Zone Valve
    Zone valves are used to control hot and chilled water in heating and air conditioning systems. Coupled with an electro-thermal control actuator and managed by a room thermostat, they allow automatic on/off control of the hydronic circuit on which they are installed. Their special feature is their compact size and they can therefore be installed almost anywhere including baseboard or directly in fan-coil units.
    $57.30

  10. Caleffi 548 Series Hydro Separator-1-1/2" Sweat Union w/Insulation

    Caleffi 548 Series Hydro Separator-1-1/2" Sweat Union w/Insulation

    Hydro Separator available in 1"-2" NPT & Sweat Unions. MAX operating pressure: 150 psi. Temperature range with insulation: 32-230 F. Medium: Water & Non-Hazardous Glycol solution. MAX percentage glycol: 50%.
    Series 548 Hydro Separator This device consists of several different functional components, each meet specific requirements, typical of the circuits used in heating and air-conditioning systems. • Hydronic separator: To keep connected hydronic circuits totally independent from each other • Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided with a valved connection with discharge piping. • Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection for maintenance purposes. The hydronic separator should be sized according to the maximum flow rate value at 2" 37 the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, crating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.
    $621.16

Items 1 to 10 of 153 total

per page
Page:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5

Grid  List 

Set Descending Direction