1-800-873-3507

TALK TO A REAL HUMAN!
(8am-5pm mst mon-fri)

Search results for 'heat exchanger'

Items 31 to 40 of 288 total

per page
Page:
  1. 2
  2. 3
  3. 4
  4. 5
  5. 6

Grid  List 

Set Descending Direction
  1. Caleffi Series 521 MixCal 3-Way Thermostatic Mixing Valve with adapter

    Caleffi Series 521 MixCal 3-Way Thermostatic Mixing Valve with adapter

    Caleffi MixCal 3-Way Thermostatic Mixing Valve
    Adjustable thermostatic and pressure balanced mixing valve for point of distribution in domestic water systems and radiant hydronic heating systems. Low-lead brass body. Internal anti-scale materials. Locking set point knob. Max. working pressure: 200 psi. Max. inlet temperature: 200ºF. Adjustable range: 85—150ºF. Gauge scale: 30—210ºF. Gauge accuracy: ± 6ºF. Gauge dial: 2" diameter. ASSE 1017 Listed. Lead Plumbing Law Compliance: (0.25% Max. weighted average lead content). Lead Plumbing Law Certified by IAPMO R&T.
    $119.71

  2. Caleffi Series 251 Discal High Capacity Auto Air Vent 1/2" NPT Female

    Caleffi Series 251 Discal High Capacity Auto Air Vent 1/2" NPT Female

    Caleffi Series 251 Discal High Capacity Auto Air Vent 1/2" NPT Female
    High-performance automatic air vent for solar heating systems. Working temperature range: -20—320ºF. Max. working pressure: 150 psi. Max. discharge pressure: 150 psi
    $55.10

  3. Caleffi Series 251 Discal 3/4" NPT Female Air Separator.

    Caleffi Series 251 Discal 3/4" NPT Female Air Separator.

    Caleffi Series 251 Discal 3/4" NPT Female Air Separator.
    Air separator for solar heating systems. Working temperature range: -20—320ºF. Max. working pressure: 150 psi. Max. discharge pressure: 150 psi. Connections: Main, ¾" NPT, female Drain, ½" NPT, female
    $76.74

  4. Caleffi Series 553 Automatic Filling Units 1/2"Union NPT Male Inlet with 1/2" NPT Female Outlet

    Caleffi Series 553 Automatic Filling Units 1/2"Union NPT Male Inlet with 1/2" NPT Female Outlet

    Caleffi Series 553 Automatic Filling Units
    The AutoFill™ automatic filling valve is a pressure reducing valve with a compensating seat, an inlet filter, a shut-off valve and a check valve. It is installed on the water inlet piping in sealed heating systems, and its main function is to maintain the pressure of the system to a preset value, automatically filling up with water as required. This valve has been designed as pre-adjustable, which means it can be adjusted at the required pressure value before charging the system. After installation, during the filling or topping-off phase, the water feed will stop automatically when the set pressure is reached. There are no levers to flip or valve to close. Preassembled with the backflow preventer, it features an atmospheric vent which is designed to protect drinking water systems from return flow, caused by back-siphoning or backpressure, of contaminated fluids. The 573 series has been specifically certified to standards CSA B64.3 and ASSE 1012.
    $50.39

  5. Caleffi Series 5213 Scald Protection Three Way Mixing Valve Sweat-3/4"

    Caleffi Series 5213 Scald Protection Three Way Mixing Valve Sweat-3/4"

    Caleffi Series 5213 Scald Protection Three Way Mixing Valve
    Adjustable, anti-scald thermostatic mixing valve. The thermostatic mixer is used in systems producing domestic hot water or in radiant panel heating systems. Its function is to maintain the temperature of the mixed water supplied to the user constant at the set value when there are variations in the supply conditions of the incoming hot and cold water. The valve has been specifically certified to ASSE 1017.
    $92.18

  6. Caleffi 548 Series Hydro Separator with ANSI Flanges-6" ANSI Flanged connection without Insulation ASME

    Caleffi 548 Series Hydro Separator with ANSI Flanges-6" ANSI Flanged connection without Insulation ASME

    Without Insulation ASME tagged and registered
    Series 548 Hydro Separator with ANSI Flanges. This device consists of several different functional components, each meet specific requirements, typical of the circuits used in heating and air-conditioning systems. • Hydronic separator: To keep connected hydronic circuits totally independent from each other • Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided with a valved connection with discharge piping. • Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection for maintenance purposes. The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.

    Regular Price: $10,280.00

    Special Price: $3,776.19

  7. Caleffi 548 Series Hydro Separator with ANSI Flanges-5" ANSI Flanged connection without Insulation ASME

    Caleffi 548 Series Hydro Separator with ANSI Flanges-5" ANSI Flanged connection without Insulation ASME

    Without Insulation-ASME tagged and registered
    Series 548 Hydro Separator with ANSI Flanges. This device consists of several different functional components, each meet specific requirements, typical of the circuits used in heating and air-conditioning systems. • Hydronic separator: To keep connected hydronic circuits totally independent from each other • Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided with a valved connection with discharge piping. • Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection for maintenance purposes. The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.

    Regular Price: $8,480.00

    Special Price: $3,114.99

  8. Caleffi 548 Series Hydro Separator with ANSI Flanges-4" ANSI Flanged connection w/Insulation

    Caleffi 548 Series Hydro Separator with ANSI Flanges-4" ANSI Flanged connection w/Insulation

    0
    Series 548 Hydro Separator with ANSI Flanges. This device consists of several different functional components, each meet specific requirements, typical of the circuits used in heating and air-conditioning systems. • Hydronic separator: To keep connected hydronic circuits totally independent from each other • Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided with a valved connection with discharge piping. • Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection for maintenance purposes. The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.

    Regular Price: $5,000.00

    Special Price: $1,836.67

  9. Caleffi 548 Series Hydro Separator with ANSI Flanges-3" ANSI Flanged connection w/Insulation

    Caleffi 548 Series Hydro Separator with ANSI Flanges-3" ANSI Flanged connection w/Insulation

    0
    Series 548 Hydro Separator with ANSI Flanges. This device consists of several different functional components, each meet specific requirements, typical of the circuits used in heating and air-conditioning systems. • Hydronic separator: To keep connected hydronic circuits totally independent from each other • Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided with a valved connection with discharge piping. • Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection for maintenance purposes. The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.

    Regular Price: $4,465.00

    Special Price: $1,640.14

  10. Caleffi Discal Series 551 Compact Air Separator 3/4" Sweat

    Caleffi Discal Series 551 Compact Air Separator 3/4" Sweat

    Air separator. Brass body. Stainless steel mesh internal element. ½" NPT bottom thread. Max. working pressure: 150 psi. Working temperature range: 32—250°F.
    Air separators are used to continuously remove the air contained in the hydronic circuits of heating and cooling systems. The air discharge capacity of these devices is very high. They are capable of removing automatically all the air present in the system down to micro-bubble level. The circulation of fully de-aerated water enables the equipment to operate under optimum conditions, free from any noise, corrosion, localized overheating or mechanical damage. Micro-bubbles, fuse together, increase in volume until they become large enough to rise to the top where they are automatically released.
    $51.82

Items 31 to 40 of 288 total

per page
Page:
  1. 2
  2. 3
  3. 4
  4. 5
  5. 6

Grid  List 

Set Descending Direction