The thermostatic mixer is used in systems producing domestic hot water or in radiant panel heating systems. Its function is to maintain the temperature of the mixed water supplied to the user constant at the set value when there are variations in the supply conditions of the incoming hot and cold water.
The valve has been specifically certified to ASSE 1017.
Hydro Separator available in 1"-2" NPT & Sweat Unions. MAX operating pressure: 150 psi. Temperature range with insulation: 32-210 F without insulation: 32-250 F. Medium: Water & Non-Hazardous Glycol solution. MAX percentage glycol: 50%.
Series 548 Hydro Separator.
This device consists of several different functional components, each meet specific
requirements, typical of the circuits used in heating and air-conditioning systems.
• Hydronic separator: To keep connected hydronic circuits totally independent from each other
• Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided
with a valved connection with discharge piping.
• Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection
for maintenance purposes.
The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.
Pro-Tek® 922 is a concentrated corrosion inhibitor treatment specially formulated for hot water closed loop heating systems.
Pro-Tek® 922 is a concentrated corrosion inhibitor treatment specially formulated for hot water closed loop heating systems. Many water sources used in hydronic heating systems can be very corrosive to metals when heated. Pro-Tek 922 will help to reduce corrosion on aluminum, brass, copper, iron, and stainless steel. Pro-Tek 922 has also been tested and is compatible with standard PEX and Onix tubing typically used in hydronic installations.
Balancing Valve with Flow Meter, offers direct reading of flow rate, no sight gauge clouding or scaling. Has brass valve body and flow meter, rotatable valve for flow rate adjustement, and graduated scale flow meter with magnetic movement flow rate indicator. MAX working pressure: 150 psi. Temperature range: 14-230 F. Max percentage of glycol: 50%.
The 132 series balancing valve accurately sets the flow rate of heating and cooling transfer fluid
supplied to fan coils and terminal units or where flow balancing is required in solar thermal
systems. Proper hydronic system balancing ensures that the system operates according to design
specifications, providing satisfactory thermal comfort with low energy consumption. The flow
meter is housed in a bypass circuit on the valve body and can be shut off during normal operation.
The flow meter permits fast and easy circuit balancing without added differential pressure gauges
and reference charts. The balancing valve is furnished with a preformed insulation shell to
optimize thermal performance or both hot and cold water systems.
Z-one valves are used to automatically shut-off the flow or redirect hot and
chilled water in hydronic heating and air conditioning systems. The motorized two position, on/off/, spring return A1 series actuator has an
end mounted push button for quick installation to valve body. The actuator is
equipped with or without auxiliary switch and configured Normally closed or
Normally Opened with wire or terminal connections.
Adjustable thermostatic and pressure
balanced mixing valve for point of
distribution in domestic water systems
and radiant hydronic heating systems.
Low-lead brass body.
Internal anti-scale materials.
Locking set point knob.
Max. working pressure: 200 psi.
Max. inlet temperature: 200ºF.
Adjustable range: 85—150ºF.
Gauge scale: 30—210ºF.
Gauge accuracy: ± 6ºF.
Gauge dial: 2" diameter.
ASSE 1017 Listed.
Lead Plumbing Law Compliance:
(0.25% Max. weighted average lead
content).
Lead Plumbing Law Certified by
IAPMO R&T.
Grundfos Brute Three Speed Bronze Recirculator Pump
The Grundfos UPS26-99BFC (52722518) model incorporates a three speed motor for increased versatility, a built-in check valve and a bronze housing for ehnaced corrosion resistance. The wet rotor design allows it to be virtually silent while operating, while built-in motor protection assures long life of the circulator. Performance parameters (flow rates and pressure drop) of the Grundfos UPS26-99BFC model make it well suited for a wide range of applications, from radiant and hydronic heating, to domestic hot water recirculatio, solar, chilled water cooling and many others.
Grundfos UPS15-35SFC is a 1/6HP, 3-Speed Circulator Pump with stainless steel housing, suitable for a wide range of open loop and closed loop applications, including radiant heating, hydronic heating, solar, hot water recirculation, chilled water cooling and many others. 3 speeds of the Grundfos UPS15-35SFC model allow to adjust pump's parameters to match system requirements and achieve optimal performance.
Grundfos UPS15-55SFC is a 1/8HP, 3-speed Stainless steel Circulator Pump with removalble Integral Check Valve and flanged connections. 3 speeds of the Grundfos UPS15-55SFC model make this pump very versatile and allow to match the system's requirements by adjusting the speeds (Low/Med/High), thus optimizing it's performance. Stainless steel body of the circulator resists corrosion and allows to use UPS15-55SFC model in a variety of applications ranging from open loop radiant and hot water recirculation, to closed loop hydronic heating and even chilled water cooling. This model also replaces a number of competitive models from Taco, Bell & Gosset, Wilo and others.
Grundfos UP15-29SU model circulator incorporates a stainless steel body design and 1-1/4" union connection, smaking it suitable for a wide range of open and closed loop radiant heating, hydronic heating, hot water recirculation, solar & other applications.