  1. Caleffi Series 253 Saftey Solar Release Valve

    Caleffi Series 253 Saftey Solar Release Valve

    Caleffi Series 253 Saftey Solar Release Valve
    Safety relief valves for solar systems. Working temperature range: -20—360ºF. Normal pressure: 150 psi. Opening over pressure: 10%. Closing differential: 20%. Discharge capacity: 171,000 BTU. Connections: Inlet, ½" female. Discharge, ¾" female.
    $29.41

  2. Caleffi Series NA255 dual-line solar pump station high head/flow w/ 3-spd Wilo Star 30 pump

    Caleffi Series NA255 dual-line solar pump station high head/flow w/ 3-spd Wilo Star 30 pump

    Caleffi Series NA255 Commercial Solar Pump Station
    Drainback solar pump stations designed with a high head and steep pump curve which are pre-assembled and leak-tested. Safety relief valve, ball valve, temperature gauge, pressure gauge, air fi ll valve. Connections for fl ushing and fi lling with foam insulation. Balance/fl ow meter: ½—5 gpm scale. Pump: Grundfos UP15-100 Performance: 36 feet head / 8 gpm. Safety relief valve: 90 psi. Max. working pressure: 150 psi. Max. working temp: 360ºF. Connections: ¾" female thread. Agency approval: cULus.
    $840.68

  3. 332-0071

    3" PHH-DV Horizontal Termination

    3 Inch Horizontal Termination for PHH-DV Series
    3 Inch Horizontal Termination for PHH-DV Series
    $30.00

  4. Caleffi Series 546 Dirtcal Dirt Separaters Brass Sweat-1 -1/4"

    Caleffi Series 546 Dirtcal Dirt Separaters Brass Sweat-1 -1/4"

    Dirt Separator. Brass Body. 1/2" NPT Top Thread With Plug For Optional Air Vent, Code 502243A Max. Working Pressure: 150 PSI. Working Temperature Range: 32-250F. Particle Separation Capacity: To 0.2 mil
    In heating and air conditioning control systems, the circulation of water containing impurities may result in rapid wear and damage to components such as pumps and control valves. It also causes blockages in heat exchangers, heating elements and pipes, resulting in lower thermal efficiency within the system. The dirt separator separates off these impurities, which are mainly made up of particles of sand and rust, collecting them in a large collection chamber, from which they can be removed even while the system is in operation. This device is capable of efficiently removing the smallest particles, with low head loss.
    $120.18

  5. Caleffi 132 Series QuickSetter Balancing Valve with Flow Meter - 3/4" NPT: 2-7 GPM

    Caleffi 132 Series QuickSetter Balancing Valve with Flow Meter - 3/4" NPT: 2-7 GPM

    Balancing Valve with Flow Meter, offers direct reading of flow rate, no sight gauge clouding or scaling. Has brass valve body and flow meter, rotatable valve for flow rate adjustement, and graduated scale flow meter with magnetic movement flow rate indicator. MAX working pressure: 150 psi. Temperature range: 14-230 F. Max percentage of glycol: 50%.
    The 132 series balancing valve accurately sets the flow rate of heating and cooling transfer fluid supplied to fan coils and terminal units or where flow balancing is required in solar thermal systems. Proper hydronic system balancing ensures that the system operates according to design specifications, providing satisfactory thermal comfort with low energy consumption. The flow meter is housed in a bypass circuit on the valve body and can be shut off during normal operation. The flow meter permits fast and easy circuit balancing without added differential pressure gauges and reference charts. The balancing valve is furnished with a preformed insulation shell to optimize thermal performance or both hot and cold water systems.
    $97.29

  6. Caleffi 548 Series Hydro Separator

    Caleffi 548 Series Hydro Separator

    Hydro Separator available in 1"-2" NPT & Sweat Unions. MAX operating pressure: 150 psi. Temperature range with insulation: 32-210 F without insulation: 32-250 F. Medium: Water & Non-Hazardous Glycol solution. MAX percentage glycol: 50%.
    Series 548 Hydro Separator. This device consists of several different functional components, each meet specific requirements, typical of the circuits used in heating and air-conditioning systems. • Hydronic separator: To keep connected hydronic circuits totally independent from each other • Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided with a valved connection with discharge piping. • Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection for maintenance purposes. The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.
    $393.41

  7. Caleffi Series 521 Mixcal Three Way Mixing Valve Sweat

    Caleffi Series 521 Mixcal Three Way Mixing Valve Sweat

    Caleffi Series 521 Mixcal Three Way Mixing Valve
    The thermostatic mixer is used in systems producing domestic hot water or in radiant panel heating systems. Its function is to maintain the temperature of the mixed water supplied to the user constant at the set value when there are variations in the supply conditions of the incoming hot and cold water. The valve has been specifically certified to ASSE 1017.
    $88.25

  8. Caleffi Series 521 Mixcal Three Way Mixing Valve Sweat-3/4"

    Caleffi Series 521 Mixcal Three Way Mixing Valve Sweat-3/4"

    Adjustable, anti-scald thermostatic mixing valve Series 521 Adjustable Thermostatic and Pressure Balanced Mixing Valve for Point of Distribution in Domestic Water Systems and Radiant Hydronic Heating Systems. Low-lead Brass Body. Internal Anti-scale Materials. Locking Set Point Knob Max. Working Pressure: 200 PSI Max. Inlet Temperature 200F Adjustable Range: 85-150F ASSE 1017 Listed. Lead Plumbing Law Compliance: (0.25% Max. Weighted Average Lead Content) Lead Plumbing Law Certified by IAPMO R&T.
    The thermostatic mixer is used in systems producing domestic hot water or in radiant panel heating systems. Its function is to maintain the temperature of the mixed water supplied to the user constant at the set value when there are variations in the supply conditions of the incoming hot and cold water. The valve has been specifically certified to ASSE 1017.
    $88.25

  9. Caleffi Series 521 Mixcal Three Way Mixing Valve Sweat-1"

    Caleffi Series 521 Mixcal Three Way Mixing Valve Sweat-1"

    Adjustable, anti-scald thermostatic mixing valve Series 521 Adjustable Thermostatic and Pressure Balanced Mixing Valve for Point of Distribution in Domestic Water Systems and Radiant Hydronic Heating Systems. Low-lead Brass Body. Internal Anti-scale Materials. Locking Set Point Knob Max. Working Pressure: 200 PSI Max. Inlet Temperature 200F Adjustable Range: 85-150F ASSE 1017 Listed. Lead Plumbing Law Compliance: (0.25% Max. Weighted Average Lead Content) Lead Plumbing Law Certified by IAPMO R&T.
    The thermostatic mixer is used in systems producing domestic hot water or in radiant panel heating systems. Its function is to maintain the temperature of the mixed water supplied to the user constant at the set value when there are variations in the supply conditions of the incoming hot and cold water. The valve has been specifically certified to ASSE 1017.
    $105.14

  10. Caleffi Series 546 Dirtcal Dirt Separaters Brass Sweat-1"

    Caleffi Series 546 Dirtcal Dirt Separaters Brass Sweat-1"

    Dirt Separator. Brass Body. 1/2" NPT Top Thread With Plug For Optional Air Vent, Code 502243A Max. Working Pressure: 150 PSI. Working Temperature Range: 32-250F. Particle Separation Capacity: To 0.2 mil
    In heating and air conditioning control systems, the circulation of water containing impurities may result in rapid wear and damage to components such as pumps and control valves. It also causes blockages in heat exchangers, heating elements and pipes, resulting in lower thermal efficiency within the system. The dirt separator separates off these impurities, which are mainly made up of particles of sand and rust, collecting them in a large collection chamber, from which they can be removed even while the system is in operation. This device is capable of efficiently removing the smallest particles, with low head loss.