The gas pressure switch is mounted on the casing of the water heater adjacent to the heater's thermostat/gas control valve. It
should be mounted close enough so that the supplied 1/4" tubing will reach from the gas pressure switch fitting to the thermostat/gas valve pressure tap port. The two provided screws are self-tapping and drilling. The screws do not require the use of a drill and their 1/2" length assures that the inner tank will not be penetrated
Enables Appliances to be Interlocked in Conjunction with UC1 universal control
The MAC4E is used in conjunction with the UC1 Universal Control to interlock up to four additional 24 VAC, 115 VAC or millivolt (Dry Contact) controlled appliances. It activates the Venter through its connections to the UC1 and in turn relies on the UC1 Fan Prover safety circuit (P1 & P2) to allow its interlocked appliances to operate. Any pre/post-purge settings on the UC1 will be defaulted to the MAC4E. Two LEDs for each appliance interlock block are provided on the MAC4E. LEDs #1, 3, 5, 7 (AMBER) shows an appliance call for heat. LEDs #2, 4, 6, 8 (GREEN) shows that the burner is approved to fire after the Venter Fan Prover safety circuit through the UC1 is completed. The MAC4E also has an LED #9 (RED) which means power is supplied to the MAC4E through the UC1.
Used as a means of increasing air flow through duct work or as an exhaust fan to vent non-combustible air or fumes from enclosed spaces. The maximum air flow operating temperature for the EF-Series is1500 F. (650 C.)
CAUTION: This device is not designed to vent bi-products of combustion or combustible fumes.
TJERNLUND AUTO-DRAFT® Inducers assure positive draft when restricted boilers and furnaces, poor chimneys or slight negative pressures in buildings prevent proper exhaust of combustion gas. The venturi action of Tjernlund Auto-Draft Inducers starts air moving smoothly. These units are quick and easy to install and completely automatic in operation. Tjernlund’s unique design and durable construction makes them trouble-free and reduces maintenance to a minimum. The Vari-Draft Control permits adjustments to the individual job requirement.
Single Acting Galvanized Draft Control For Oil, Solid Fuel and Fan Assisted Gas Burners
Heating appliances are designed to operate with a consistent draft. Chimney configurations, mechanical draft fans and weather can cause draft fluctuations. These fluctuations result in inefficient combustion and more frequent service
calls. Draft controls regulate the airflow through a chimney or vent. By diluting the chimney/vent draft with varying amounts of room air they maintain the draft at a heater's flue outlet within a consistent, safe and efficient range.
This single acting control is made of galvanized steel for low maintenance and corrosion resistance. It has integral anchor points and self- aligning, self-centering rocker bearings for long lasting service. A cushioned stop minimizes rattle and noise. Adjustment is easily accomplished by moving counter weight on outside tab.
TJERNLUND AUTO-DRAFT® Inducers assure positive draft when restricted boilers and furnaces, poor chimneys or slight negative pressures in buildings prevent proper exhaust of combustion gas. The venturi action of Tjernlund Auto-Draft Inducers starts air moving smoothly. These units are quick and easy to install and completely automatic in operation. Tjernlund’s unique design and durable construction makes them trouble-free and reduces maintenance to a minimum. The Vari-Draft Control permits adjustments to the individual job requirement.
This Safety Interlock System may be used on conventional chimney or Power Vented appliances equipped with a draft hood, draft diverter or draft control. It's purpose is to provide a means for appliance shut-down in the event of flue blockage or down drafts. The Spill Switch circuits are “normally closed” and will not affect normal appliance operation. When concentrated spillage of combustion gases occurs from the draft hood, diverter or barometric control, the Spill Switch circuit will open preventing burner operation.
***WARNING*** The 24SP200 Flue Gas Spillage Sensing Kit is designed to alert the user to a potentially
hazardous condition. It is not designed to, and cannot replace regular chimney inspection,
appliance servicing and combustion testing. DO NOT USE THE 24SP200 AS A SUBSTITUTE
FOR PROFESSIONAL APPLIANCE MAINTENANCE.
Grundfos UPS15-35SFC is a 1/6HP, 3-Speed Circulator Pump with stainless steel housing, suitable for a wide range of open loop and closed loop applications, including radiant heating, hydronic heating, solar, hot water recirculation, chilled water cooling and many others. 3 speeds of the Grundfos UPS15-35SFC model allow to adjust pump's parameters to match system requirements and achieve optimal performance.
Grundfos UPS15-55SFC is a 1/8HP, 3-speed Stainless steel Circulator Pump with removalble Integral Check Valve and flanged connections. 3 speeds of the Grundfos UPS15-55SFC model make this pump very versatile and allow to match the system's requirements by adjusting the speeds (Low/Med/High), thus optimizing it's performance. Stainless steel body of the circulator resists corrosion and allows to use UPS15-55SFC model in a variety of applications ranging from open loop radiant and hot water recirculation, to closed loop hydronic heating and even chilled water cooling. This model also replaces a number of competitive models from Taco, Bell & Gosset, Wilo and others.