Hydro Separator available in 1"-2" NPT & Sweat Unions. MAX operating pressure: 150 psi. Temperature range with insulation: 32-210 F without insulation: 32-250 F. Medium: Water & Non-Hazardous Glycol solution. MAX percentage glycol: 50%.
Series 548 Hydro Separator.
This device consists of several different functional components, each meet specific
requirements, typical of the circuits used in heating and air-conditioning systems.
• Hydronic separator: To keep connected hydronic circuits totally independent from each other
• Dirt remover: To permit the separation and collection of any impurities present in the circuits. Provided
with a valved connection with discharge piping.
• Automatic air vent valve: For automatic venting of any air contained in the circuits. Provided with a valved connection
for maintenance purposes.
The hydronic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit. When a single system contains a primary production circuit, with its own pump, and a secondary user circuit, with one or more distribution pumps, operating conditions may arise in the system whereby the pumps interact, creating abnormal variations in circuit flow rates and pressures. The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other if the pressure loss in the common section is negligible. In this case, the flow rate in the respective circuits depends exclusively on the flow rate characteristics of the pumps, preventing reciprocal influence caused by connection in series. Therefore, using a device with these characteristics means that the flow in the secondary circuit only circulates when the relevant pump is on, permitting the system to meet the specific load requirements at that time. When the secondary pump is off, there is no circulation in the secondary circuit; the whole flow rate produced by the primary pump is by-passed through the separator. With the hydronic separator, it is thus possible to have a primary production circuit with a constant flow rate and a secondary distribution circuit with a variable flow rate; these operating conditions are typical of modern heating and cooling systems.
The thermostatic mixer is used in systems producing domestic hot water or in radiant panel heating systems. Its function is to maintain the temperature of the mixed water supplied to the user constant at the set value when there are variations in the supply conditions of the incoming hot and cold water.
The valve has been specifically certified to ASSE 1017.
Caleffi Series 5213 Scald Protection Three Way Mixing Valve
Adjustable, anti-scald thermostatic mixing valve.
The thermostatic mixer is used in systems producing domestic hot water or in radiant panel heating systems. Its function is to maintain the temperature of the mixed water supplied to the user constant at the set value when there are variations in the supply conditions of the incoming hot and cold water.
The valve has been specifically certified to ASSE 1017.
The AutoFill™ automatic filling valve is a pressure reducing valve with
a compensating seat, an inlet filter, a shut-off valve and a check valve.
It is installed on the water inlet piping in sealed heating systems, and
its main function is to maintain the pressure of the system to a preset
value, automatically filling up with water as required. This valve has been
designed as pre-adjustable, which means it can be adjusted at the required
pressure value before charging the system. After installation, during the
filling or topping-off phase, the water feed will stop automatically when the
set pressure is reached. There are no levers to flip or valve to close. Preassembled with the backflow preventer, it features an atmospheric vent
which is designed to protect drinking water systems from return flow, caused
by back-siphoning or backpressure, of contaminated fluids. The 573 series
has been specifically certified to standards CSA B64.3 and ASSE 1012.
Automatic air vent with service check valve.
Brass body.
Max. working pressure: 150 psi.
Max. discharge pressure: 90 psi.
Max. working temperature: 240°F.
Z-one valves are used to automatically shut-off the flow or redirect hot and
chilled water in hydronic heating and air conditioning systems. The motorized two position, on/off/, spring return A1 series actuator has an
end mounted push button for quick installation to valve body. The actuator is
equipped with or without auxiliary switch and configured Normally closed or
Normally Opened with wire or terminal connections.
Z-one valves are used to automatically shut-off the flow or redirect hot and
chilled water in hydronic heating and air conditioning systems. The motorized two position, on/off/, spring return A1 series actuator has an
end mounted push button for quick installation to valve body. The actuator is
equipped with or without auxiliary switch and configured Normally closed or
Normally Opened with wire or terminal connections.